The T7000 series networked LCD thermostat is used for temperature control in water systems or air systems. By comparing the ambient temperature with the set temperature, it controls the operating status of the fan coil unit, electric valve, electric ball valve, or air damper of the air conditioning terminal to achieve the purpose of regulating ambient temperature, comfort, and energy saving. The thermostat adopts microcomputer control technology, features an extra-large LCD screen, elegant design, and is easy to use. Through buttons, heating and cooling modes can be selected, and the desired indoor temperature can be set.
Technical Specifications
Temperature Sensor: NTC Thermistor
Control Accuracy: ±1℃
Temperature Setting: 5-35℃
Display Range: 0-50℃
Operating Environment: 0-45℃
Humidity: 5-95% RH (non-condensing)
Display: LCD
Power Supply Voltage: AC180-260V, 50/60Hz
Self-consumption Power: <1W
Load Power: <220W
Terminal: Can connect 2×1.5mm² or 1×2.5mm² wires
Housing: PC+ABS flame retardant
Dimensions: 86×86×13mm (width*height*thickness)
Mounting Hole Distance: 60mm (standard)
Display Status
Operating Mode (Cooling, Heating)
Fan Speed (High, Medium, Low, Auto)
Display Indoor Temperature
Display Set Temperature
Operation Instructions
Power On/Off | Press the button once to turn on, press again to turn off |
Temperature Setting | When powered on, press the "▼" key to decrease the set temperature, press the "▲" key to increase the set temperature, each press changes the temperature by 1℃ |
Mode Selection | When powered on, press the mode key to switch; LCD displays "Cooling" for cooling mode, "Heating" for heating mode |
Fan Speed Selection | Press the fan speed key to select fan speed: High, Medium, Low, Auto. In "Auto" speed mode, the fan speed automatically adjusts: when the indoor temperature differs from the set temperature by more than 6℃, it automatically selects high speed; when the difference is between 3-6℃, it automatically selects medium speed; when the difference is within 3℃, it automatically selects low speed. |
Sleep Function | Long press the mode key for 3 seconds to switch to sleep display status, press "▼" to confirm, press "▲" to cancel After sleep is activated, in cooling mode, the set temperature increases by 1℃ per hour, up to 3℃; in heating mode, the set temperature decreases by 1℃ per hour, up to 3℃; |
Timer Function | In sleep display status, press the mode key again to enter the timer on/off setting. When the timer off is activated, in the on mode, the thermostat turns off immediately when the set time is reached; when the timer on is activated, the thermostat starts timing after it is turned off and turns on immediately when the set time is reached. |
Key Lock | When powered on, simultaneously press the plus and minus keys for 3 seconds to lock or unlock the keys. In the locked state, the LCD displays a lock symbol. |
Clock Setting | When powered on, long press the mode key for 3 seconds to enter the clock setting function. After entering, the minutes start flashing; press the fan speed key to cycle through "minutes-hours-day of the week," use the plus and minus keys to adjust, and press the power key to exit after setting. |
Fan Mode | When powered on, simultaneously press the mode key and minus key for 3 seconds to select whether the fan is controlled. Fan not controlled: Controls the two-wire electric valve and three-speed fan; when the temperature is reached, the electric valve closes, and the fan continues to run. In fan not controlled mode, the LCD displays the "Comfort" answer. |
View Running Time | When powered on, long press the fan speed key and minus key for 5 seconds to view the running time; press the mode key and fan speed key to switch time status. |
Installation Notes
1.Cut off the power during installation. Configure a power switch to cut off the power when not in use for heating.
2.The installation position should be about 1.4m from the floor, avoiding direct sunlight, drafts, and away from heat sources, in a location representative of the room temperature.
3.Connect the circuit according to the base wiring diagram. If the thermostat used does not match the provided installation diagram, please contact the distributor or factory.
4.Configure the load according to the marked current; overload is prohibited.
5.Please refer to the provided wiring diagram for correct wiring.